Abstract
The documents titled Supported Hardware List and Recommended Software Levels provide the operating systems, Host adapters, SAN fabric elements, RAID controllers and selected other hardware that have been tested or qualified by IBM. This page combines the previously separate Software and Hardware support matrices.
For operating systems, we show the latest tested release levels and service packs. Only the listed operating systems are supported. For host adapters, SAN fabric elements and RAID controllers, we list our currently recommended firmware and/or BIOS levels and formally support only the hardware listed.
While these levels are not mandatory levels for a customer to be supported by IBM, they are the recommended levels. There may be known operational issues with older firmware and BIOS levels and, in these cases, a customer working with the IBM Support center may be directed to upgrade a component to a recommended level.
SVC will support all OS applications at any level that run to the standard block level OS interface. This includes such applications as Oracle, HP Virtual Connect, etc.
Note:
* The levels shown in italic text indicate previously recommended levels.
* The level shown in bold text indicates the latest recommended level.
* EOL - (End of Life):
Where interoperability items have gone end of life (out of support) and are no longer supported by the vendor either generally or by extended service contact IBM will continue to support the environment on a best can do basis. Where issues occur which are deemed by IBM support to be directly related to items which are no longer generally supported by the vendor IBM may direct customers to upgrade a component to a recommended level.
Content
IMPORTANT NOTICE: SAN Volume Controller V6.1.x is no longer supported. Refer to the SAN Volume Controller Support Statement for further information.--
Previous Support Levels | |
Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller Recommended Software Levels for SAN Volume Controller | |
4.3.x | Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller Recommended Software Levels for SAN Volume Controller |
Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller Recommended Software Levels for SAN Volume Controller | |
4.1.x | Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller Recommended Software Levels for SAN Volume Controller |
Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller Recommended Software Levels for SAN Volume Controller | |
2.1.x | Supported Hardware List, Device Driver and Firmware Levels for SAN Volume Controller Recommended Software Levels for SAN Volume Controller |
---
Last Updated | |
Easy Tier Function Supported Configurations | |
SAN Volume Controller Code Level V6.1.0 | 18 Aug 2011 |
VIOS | 27 Aug 2014 |
Windows 2003 Server using MPIO | |
Windows 2008 Server using MPIO | 05 Sep 2013 |
Windows 2008 Server-Hyper-V | |
Red Hat EL 4.0 *End of Life* | 11 Feb 2014 |
Red Hat EL 5.0 | |
SLES 8 SP4 *End of Life* | 11 Feb 2014 |
SLES 9 *End of Life* | |
SLES10 | 04 Nov 2013 |
SLES11 | |
Debian | 07 Oct 2010 |
Novell OES2 | |
HP-UX 11i v1 | 07 Oct 2010 |
HP-UX 11i v2 | |
HP-UX 11i v3 | 12 Jan 2015 |
Sun Solaris 8 *End of Life* | |
Sun Solaris 9 | 11 Feb 2014 |
Sun Solaris 10 | |
Novell Netware *End of Life* | 11 Feb 2014 |
VMWare SRM | |
05 Jun 2014 | |
Tru64 | |
OpenVMS | 22 Feb 2011 |
IBM N Series Gateway and NetApp | |
07 Oct 2010 | |
z/VSE | |
z/VM | 01 Sep 2014 |
Apple Mac OS X | |
VIOS | 07 Oct 2010 |
Citrix Xen Server | |
iSCSI Host Attachment | 07 Oct 2010 |
Support for BladeServer Configurations | 07 Oct 2010 |
HS & LS Models | |
JS Power Models | 27 Aug 2014 |
HP BladeSystem | |
Storwize V7000 | 07 Oct 2010 |
DS3000 | |
DS4000 | 07 Oct 2010 |
DS5000 | |
DS6000 | 07 Oct 2010 |
DS8000 | |
IBM ESS | 07 Oct 2010 |
XIV | |
HP | 29 Apr 2014 |
Hitachi Data Systems | |
EMC | 07 Oct 2010 |
Sun StorEdge | |
StorageTek | 07 Oct 2010 |
IBM N Series Filer and NetApp FAS | |
Fujitsu Eternus | 07 Oct 2010 |
Bull Storeway | |
NEC iStorage | 22 Feb 2011 |
Pillar Data | |
Texas Memory Systems | 07 Oct 2010 |
Xiotech | |
Nexsan | 07 Oct 2010 |
Dell Compellent | |
Switches | |
ISL Blades | |
BladeCenter Supported Configurations | 07 Oct 2010 |
Brocade FC Brocade Converged Network Switches | |
Cisco MDS Cisco Nexus | 24 Sep 2014 |
McDATA | |
Qlogic | 07 Oct 2010 |
Inter Cluster Fibre Channel Extenders | 07 Oct 2010 |
Inter Cluster SAN Routers | |
IBM System Storageā¢ TS7650G ProtecTIER De-duplication Gateway | 07 Oct 2010 |
VSS | |
GPFS / RVSD Versions | 07 Oct 2010 |
TotalStorage Productivity Center for Disk | |
TotalStorage Productivity Center for Replication | 07 Oct 2010 |
Oracle |
SVC Easy Tier Function Supported Configurations
Tier 1 Storage | |
Internal SSDs (within SVC nodes) | Easy Tier is not supported in any configuration where SSDs are not exclusively being used as the Tier 0 storage. |
Externally virtualized SAS or NL-SAS |
SAN Volume Controller Code Level V6.1.0
Version |
IBM AIX on Power Systems
IBM Legacy AIX Versions
Host Bus Adapter | HBA Firmware | |
IBM AIX 4.3.3 | Driver included in Technology Level. | IBM System p These Operating Systems are now end of service and as such no further fixes will be made available. Should you have an issue please upgrade to a supported version of AIX |
3.93a0 | ||
FC6227 | ||
FC6228 | ||
FC6239 | ||
IBM AIX 5.2 | ||
1.91X4 1.92a1 | ||
2.10X8 2.71X4 | ||
2.10X8 2.71X4 | ||
2.71a2 2.71x15 |
IBM AIX Currently Supported Versions
---
Host Bus Adapter | Multipath Driver | SAN Boot | ||
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 570 (9117-MMA) IBM Power 575 (9125-F2A) IBM Power 595 (9119-FHA) IBM Power 720 (8202-E4B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) IBM Power 770 (9117-MMB) IBM Power 780 (9179-MHB) IBM Power 795 (9119-FHB) | Driver included in Technology Level | SDDPCM 2.6.0.3 SDDPCM 2.6.1.0 SDDPCM 2.6.3.2 SDDPCM2.6.4.0 SDDPCM 2.6.5.1 | Yes | System i System p AIX 5.3 Technology Level 12 EOL: extended service contract only. AIX 6.1 Technology Level 1 Technology Level 2 Technology Level 3 Technology Level 4 Technology Level 5 Technology Level 6 Technology Level 7 Technology Level 8 Technology Level 9 AIX 7.1 |
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 720 (8202-E4B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) | ||||
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 570 (9117-MMA) IBM Power 575 (9125-F2A) IBM Power 595 (9119-FHA) IBM Power 720 (8202-E4B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) IBM Power 770 (9117-MMB) IBM Power 780 (9179-MHB) IBM Power 795 (9119-FHB) IBM Power 795 (9119-FHB) | ||||
Veritas DMP ( Not supported on AIX 7.1 ) | Veritas Storage Foundation HA 5.0 & 5.1 ( Not supported on AIX 7.1 ) | |||
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 560 (8234-EMA) IBM Power 570 (9117-MMA) IBM Power 575 (9125-F2A) IBM Power 595 (9119-FHA) IBM Power 720 (8202-E4B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) IBM Power 755 (8236-E8C) IBM Power 770 (9117-MMB) IBM Power 780 (9179-MHB) IBM Power 795 (9119-FHB) | ||||
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 560 (8234-EMA) IBM Power 570 (9117-MMA) IBM Power 575 (9125-F2A) IBM Power 595 (9119-FHA) IBM Power 710 (8231-E2B) IBM Power 720 (8202-E4B) IBM Power 730 (8231-E2B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) IBM Power 755 (8236-E8C) IBM Power 770 (9117-MMB) IBM Power 780 (9179-MHB) IBM Power 795 (9119-FHB) |
IBM Virtual I/O Server ( VIOS )
Supported Server Model | HBA Driver | Clustering | Platform & OS Version | |
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 570 (9117-MMA) IBM Power 575 (9125-F2A) IBM Power 595 (9119-FHA) IBM Power 720 (8202-E4B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) IBM Power 770 (9117-MMB) IBM Power 780 (9179-MHB) IBM Power 795 (9119-FHB) | Driver included in VIOS version | SDDPCM 2.6.0.3 SDDPCM 2.6.3.2 SDDPCM2.6.4.0 SDDPCM 2.6.5.1 | Yes | VIOS 2.1 VIOS 2.2 System i System p AIX, Linux Clients IBM i Client Versions 7.1 TR1 and 6.1.1 ( non NPIV ) Please see the following APAR when using the System i family OS NPIV is supported with FC 5735 and FC 5708 HBAs |
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 720 (8202-E4B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) | ||||
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 570 (9117-MMA) IBM Power 575 (9125-F2A) IBM Power 595 (9119-FHA) IBM Power 720 (8202-E4B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) IBM Power 770 (9117-MMB) IBM Power 780 (9179-MHB) IBM Power 795 (9119-FHB) IBM Power 795 (9119-FHB) | ||||
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 560 (8234-EMA) IBM Power 570 (9117-MMA) IBM Power 575 (9125-F2A) IBM Power 595 (9119-FHA) IBM Power 720 (8202-E4B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) IBM Power 755 (8236-E8C) IBM Power 770 (9117-MMB) IBM Power 780 (9179-MHB) IBM Power 795 (9119-FHB) | ||||
IBM Power 520 (8203-E4A) IBM Power 550 (8204-E8A) IBM Power 560 (8234-EMA) IBM Power 570 (9117-MMA) IBM Power 575 (9125-F2A) IBM Power 595 (9119-FHA) IBM Power 710 (8231-E2B) IBM Power 720 (8202-E4B) IBM Power 730 (8231-E2B) IBM Power 740 (8205-E6B) IBM Power 750 (8233-E8B) IBM Power 755 (8236-E8C) IBM Power 770 (9117-MMB) IBM Power 780 (9179-MHB) IBM Power 795 (9119-FHB) |
Windows 2003 Server (Using MPIO)
Host Bus Adapter | HBA Driver | Clustering | Platform & OS Version | ||||
IBM | BIOS 1.52 BIOS 1.54 | STOR Miniport 9.1.4.15 9.1.7.16 9.1.7.18 9.1.8.25 9.1.9.25 | SDDDSM 2.4.2.1-2 2.4.2.2-3 2.4.3.1-1 2.4.3.1-2 2.4.3.3-2 2.4.3.3-5 2.4.3.4-4 | SAN Volume Controller supports up to 8 Windows 2003 nodes per MSCS cluster | Yes Please visit the V6.1.x Software Restrictions document for information regarding Windows SAN Boot Clusters (MSCS) | Intel/AMD Windows 2003 32 & 64bit Editions Standard Edition Enterprise Edition Datacenter Edition Standard x64 Edition Enterprise x64 Edition Datacenter x64 Edition SP2 R2 SP2 | Please install Veritas Storage Foundation (tm) and High Availability Solutions for Windows 5.0 Rollup Patch 1a (RP1a) Windows 2003 R2 is supported. Please refer to the following link for additional support information Microsoft Virtual Server is supported. Windows Server 2003 R2 Partners |
QLA2310/F QLA2310/FL | No | ||||||
QLA2342 QLA2342L | MSCS with Veritas Volume Manager 5.1 | ||||||
39M5894 | Multiflash Image 1.56 (BIOS 1.24) Multiflash Image 1.79 (BIOS 2.10) | ||||||
QLA2462 | VERITAS Storage Foundation High Availability Clustering 5.0 | ||||||
39R6525 | |||||||
39R6527 | |||||||
42D0501 42D0510 | VERITAS Storage Foundation High Availability Clustering 5.1 | ||||||
IBM | SDDDSM 2.4.2.1-2 2.4.2.2-3 2.4.3.1-1 2.4.3.1-2 2.4.3.3-2 2.4.3.3-5 2.4.3.4-4 | SAN Volume Controller supports up to 8 Windows 2003 nodes per MSCS cluster | Yes Please visit the V6.1.x Software Restrictions document for information regarding Windows SAN Boot Clusters (MSCS) | Intel/AMD Windows 2003 32 & 64 bit Editions Windows 2003 32 & 64bit Editions Standard Edition Enterprise Edition Datacenter Edition Standard x64 Edition Enterprise x64 Edition Datacenter x64 Edition SP2 R2 SP2 | Please install Veritas Storage Foundation (tm) and High Availability Solutions for Windows 5.0 Rollup Patch 1a (RP1a) Windows 2003 R2 is supported. Please refer to the following link for additional support information Microsoft Virtual Server is supported. Windows Server 2003 R2 Partners | ||
MSCS with Veritas Volume Manager 5.1 | |||||||
LP9402DC | MSCS with Veritas Volume Manager 5.1 | ||||||
LP9802DC LP1050, LP1050DC LP1050Ex, LP1050ExDC LP10000, LP10000DC LP10000ExDC LP1005DCCM2 | |||||||
VERITAS Storage Foundation High Availability Clustering 5.0 | |||||||
LP11000 LP11002 LP1150 | VERITAS Storage Foundation High Availability Clustering 5.1 | ||||||
LPe11000 LPe11002 LPe1150 | |||||||
LP12000 LP12002 LPe12000 LPe12002 | |||||||
IBM | 1.1.0.x 2.1.0.x | SDDDSM 2.4.2.1-2 2.4.2.2-3 2.4.3.1-1 2.4.3.1-2 2.4.3.3-2 2.4.3.3-5 2.4.3.4-4 | Yes | Intel/AMD Windows 2003 32 & 64bit Editions Standard Edition Enterprise Edition Datacenter Edition Standard x64 Edition Enterprise x64 Edition Datacenter x64 Edition SP2 R2 SP2 | Windows 2003 R2 is supported. Please refer to the following link for additional support information Microsoft Virtual Server is supported. Windows Server 2003 R2 Partners | ||
415 425 815 825 | |||||||
1010/1020 |
Windows 2008 Server (Using MPIO)
HBA Firmware | Multipathing | SAN Boot | Virtualisation | ||||
IBM | BIOS 1.52 BIOS 1.54 BIOS 2.10 | STOR Miniport 9.1.4.15 9.1.7.16 9.1.7.18 9.1.8.17 9.1.8.25 9.1.9.25 | SDDDSM 2.4.2.1-2 2.4.2.2-3 2.4.3.1-1 2.4.3.1-2 2.4.3.3-2 2.4.3.3-5 2.4.3.4-4 | Yes Please visit the V6.1 Software Restrictions document for information regarding Windows SAN Boot Clusters (MSCS) SAN Boot is not supported with Qlogic Driver 9.1.8.25 | Intel/AMD Standard Edition Enterprise Edition Datacenter Edition Standard x64 Edition Enterprise x64 Edition Datacenter x64 Edition SP1 SP2 R2 | Hyper-V on x64 based systems is supported with the following guest OS Windows 2003 32bit Windows 2003 64bit Windows 2008 32bit Windows 2008 64bit With SDDDSM | Please visit the SAN Volume Controller Information Center for configuration details & Guidelines for Hyper-V Please see the SAN Volume Controller Information Center for recommended settings for QLE2560/QLE2562 & Emulex HBAs Cluster Shared Volumes are supported with Hyper-V |
QLA2340 QLA2340L QLA2342 QLA2342L | |||||||
QLA2460 | Multiflash Image 1.56 (BIOS 1.24) Multiflash Image 1.79 (BIOS 2.10) Multiflash Image 2.12 (BIOS 2.10) | No | |||||
39M5895 | DMPDSM | VERITAS Storage Foundation High Availability Clustering 5.0 | |||||
QLE2460 | |||||||
39R6527 | VERITAS Storage Foundation High Availability Clustering 5.1 | ||||||
QLE2560 QLE2562 | |||||||
QLE8142 | 9.1.8.26 | ||||||
IBM | 1.92a1 | Storport Driver 2.00a12 2.10a4 2.10a7 2.20.006 2.32.002 | SDDDSM 2.4.2.1-2 2.4.2.2-3 2.4.3.1-1 2.4.3.1-2 2.4.3.3-2 2.4.3.3-5 2.4.3.4-4 | Yes Please visit the V6.1 Software Restrictions document for information regarding Windows SAN Boot Clusters (MSCS) | Hyper-V on x64 based systems is supported with the following guest OS Windows 2003 32bit Windows 2003 64bit Windows 2008 32bit Windows 2008 64bit With SDDDSM | Please visit the V6.1 SAN Volume Controller Controller restrictions Document for restrictions when running Hyper-V Please visit the SAN Volume Controller Information Center for configuration details & Guidelines for Hyper-V Please see the SAN Volume Controller Information Center for recommended settings for QLE2560/QLE2562 & Emulex HBAs Cluster Shared Volumes are supported with Hyper-V | |
LP9802DC LP1050, LP1050DC LP1050Ex, LP1050ExDC LP10000, LP10000DC LP10000ExDC LP1005DCCM2 | |||||||
No | |||||||
DMPDSM | VERITAS Storage Foundation High Availability Clustering 5.0 | ||||||
VERITAS Storage Foundation High Availability Clustering 5.1 | |||||||
2.72a2 2.82a3 | |||||||
1.10a5 1.11a5 2.00a3 | |||||||
Brocade | 1.1.0.x 2.1.0.x | SDDDSM 2.4.2.1-2 2.4.2.2-3 2.4.3.1-1 2.4.3.1-2 2.4.3.3-2 2.4.3.3-5 2.4.3.4-4 | Yes | Intel/AMD Standard Edition Enterprise Edition Datacenter Edition Standard x64 Edition Enterprise x64 Edition Datacenter x64 Edition SP1 SP2 R2 | |||
59Y1987 59Y1993 46M6049 46M6050 | |||||||
42C1820 | 1010/1020 |
Red Hat Server 4.0 *End of Life*
HBA Driver | Multipathing | SAN Boot | Notes | |||
QLA2310/F QLA2310/FL | 8.01.06 8.01.06 8.01.07-d4 8.02.08 8.02.09-d0-RHEL4.7-04 (RHEL4.7 Distro) 8.02.14.01 8.02.09.00.04.08-D (RHEL4.8 Distro) | Device Mapper Multipath | Yes | Intel/AMD U4 2.6.9-42 EL Kernel U5 2.6.9-55 EL Kernel U7 2.6.9.78.0.1 U8 2.6.9.89 | Please see flash below before upgrading your HBA drivers Linux 2.6 Device Driver Issues with Levels Qlogic 8.01.07 or Higher and Emulex 8.16.34 or Higher Volume expansion & contraction is not supported | |
QLA2340 QLA2340L | ||||||
QLA2342 QLA2342L | ||||||
QLA2460 | ||||||
39R6525 | ||||||
39M5895 | ||||||
39R6527 | ||||||
42D0501 42D0510 | 4.04.00 | |||||
8.0.16.27 8.0.16.34 8.0.16.40 8.0.16.44 8.0.16.46 | ||||||
LP9002 | ||||||
VSF 5.0 HA Maintenance Pack 3 VRTSibmsvc-5.0-1.1_RHEL4.i686.rpm VRTSibmsvcapm-5.0-1.1_RHEL4.x86_64.rpm | ||||||
2.70a5 2.72a2 | ||||||
LP11002 | ||||||
LPe11000 | ||||||
LPe1150 | ||||||
1.10a5 | ||||||
No | IBM System p | Fabric maintenance and CCL restrictions apply, please visit Software Restrictions for further details Volume expansion & contraction is not supported | ||||
FC3319 SX/LX FC 3320 SX/LX Ficon Express 4, 10km LX: #3321 Ficon Express 4, SX: #3322 Ficon Express 4, 4km LX: #3324 | Device Mapper Multipath | No | IBM System z Requires a minimum RHEL 4 kernel level of zLinux RHEL4U4, 2.6.9-42.EL.m3 Supported Machines: System z z800 - IBM 2066 System z z800 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 System z z9-109 System z z10 2097-E12 System z z10 2097-E26 System z z10 2097-E40 System z z10 2097-E56 System z z10 2097-E64 Restrictions apply, please visit the Software restrictions document |
Red Hat EL Advanced Server 5
Host Bus Adnapter | HBA Firmware | Clustering | Platform & OS Version | |||||
IBM | 8.01.07 8.01.07-K1 8.01.07-K7 8.02.00-k5-rhel5.2-04 8.02.00.06.05.03-k 8.03.00.10.05.04-k 8.03.01.04.05.05-k | Multiflash Image 1.56 (BIOS 1.24) Multiflash Image 1.69 (BIOS 2.02) | Red Hat Cluster server Steeleye Lifekeeper 7.0 | 32 & 64 bit Intel/AMD Based Platforms 5.0 Kernel 2.6.18-8.el5 U1 Kernel 2.6.18-53.el5 U2 Kernel 2.6.18-92.1.6.el5 U3 Kernel 2.6.18-128.el5 U4 Kernel 2.6.18-164.el5 U5 Kernel 2.6.18-194.el5 U6 Kernel 2.6.18-238.el5 U7 Kernel 2.6.18-274.el5 U8 Kernel 2.6.18-308.el5 U9 Kernel 2.6.18-348.el5 | ||||
QLA2340 | ||||||||
39M5894 | ||||||||
39M5895 | ||||||||
39R6525 | ||||||||
39R6527 | ||||||||
39M5894 | ||||||||
QLA2462 | ||||||||
QLE2560 QLE2562 | ||||||||
IBM | 8.1.10.3 8.2.0.22 8.2.0.33 8.2.0.33.3p 8.2.0.48.2p 8.2.0.63.3p | |||||||
LP9802 LP10000 LP10000DC LP11000 LP11002 LPe11000 LPe11002 LP1150 LPe1150 | Veritas Storage Foundation HA 5.0 & 5.1 | |||||||
1.20x8 2.70a5 2.72a2 | ||||||||
1.11a5 | ||||||||
FC3319 SX/LX FC 3320 SX/LX Ficon Express 4, 10km LX: #3321 Ficon Express 4, SX: #3322 Ficon Express 4, 4km LX: #33245735LPe12002 | zfcp 8.1.10.3 8.2.0.22 8.2.0.33 8.2.0.33.3p 8.2.0.48.2p 8.2.0.63.3p | No | IBM System z Requires a minimum RHEL 4 kernel level of zLinux RHEL4U4, 2.6.9-42.EL.m3 Supported Machines: System z z800 - IBM 2066 System z z800 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 System z z9-109 System z z10 2097-E12 System z z10 2097-E26 System z z10 2097-E40 System z z10 2097-E56 System z z10 2097-E64 | |||||
IBM | Device Mapper Multipath | No | IBM System p 5.0 Kernel 2.6.18-8.el5 U1 Kernel 2.6.18-53.el5 U2 Kernel 2.6.18-92.1.6.el5 U3 Kernel 2.6.18-128.el5 U4 Kernel 2.6.18-164.el5 U5 Kernel 2.6.18-194.el5 U6 Kernel 2.6.18-238.el5 U7 Kernel 2.6.18-274.el5 U8 Kernel 2.6.18-308.el5 U9 Kernel 2.6.18-348.el5 | |||||
5716 | ||||||||
5773 5774 | 1.20x8 2.70a5 2.72a2 | |||||||
LP11002 LP11000 LP11002 LP11002 | ||||||||
5735 | 1.11a5 | |||||||
Brocade 415 Brocade 815 Brocade 425 Brocade 825 | 1.1.0.x 2.1.0.x | No | 32 & 64 bit Intel/AMD Based Platforms U3 Kernel 2.6.18-128.el5 U4 Kernel 2.6.18-164.el5 U5 Kernel 2.6.18-194.el5 U6 Kernel 2.6.18-238.el5 U7 Kernel 2.6.18-274.el5 U8 Kernel 2.6.18-308.el5 U9 Kernel 2.6.18-348.el5 | |||||
CNA Support | ||||||||
Brocade 1010/1020 CNA | No | 32 & 64 bit Intel/AMD Based Platforms U3 Kernel 2.6.18-128.el5 U4 Kernel 2.6.18-164.el5 U5 | ||||||
42C1800 | 8.03.00.08.10.3-k4+ DD | Device Mapper Multipath | No | 32 & 64 bit Intel/AMD Based Platforms U3 Kernel 2.6.18-128.el5 U4 Kernel 2.6.18-164.el5 U5 Kernel 2.6.18-194.el5 |
SLES 8 United Linux 1.0 SP4 *End of Life*
Host Bus Adapter | HBA Firmware | Clustering | Platform & OS Version | |||
IBM | ||||||
FC-2 P/N 19K1246 | 7.07.05 7.07.06 | No | SAN boot (IPL) is supported from SVC however the IPL processes can fail because there is no multipath support during the boot process | |||
QLA2340 QLA2340L | ||||||
QLA2342 QLA2342L | ||||||
No | SAN boot (IPL) is supported from SVC however the IPL processes can fail because there is no multipath support during the boot process | |||||
FC 2319 LX FC 2320 SX | IBM System z | No | Requires a minimum SLES 8 kernel of 2.4.21-295 with fix for IBM bugzilla 16690. Supported Machines: System z z800 - IBM 2066 System z z890 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 |
SLES 9 Novell/SuSE *End of Life*
HBA Driver | Multipathing | SAN Boot | Notes | |||
QLA2310F QLA2310FL | Steeleye Lifekeeper 6.3 7.0 Linux HA- Heartbeet 1.2.5 | 32 & 64 bit Intel/AMD Based Platforms SP3 2.6.5-7.276 Kernel SP4 2.6.5-7.308 Kernel 2.6.5-7.311 Kernel 2.6.5-7.312 Kernel | Please see flash below before upgrading your HBA drivers Linux 2.6 Device Driver Issues with Levels Qlogic 8.01.07 or Higher and Emulex 8.16.34 or Higher Volume expansion & contraction is not supported | |||
QLA2340 QLA2340L | ||||||
QLA2342 QLA2342L | ||||||
QLA2460 | Multiflash Image 1.56 (BIOS 1.24) Multiflash Image 1.69 (BIOS 2.02) | |||||
QLE2460 | ||||||
QLA2462 | ||||||
QLE2462 | ||||||
QLE2560 QLE2562 | ||||||
LP9802 | Veritas DMP | No | ||||
LP10000 LP10000DC | ||||||
LP11000 | ||||||
LP1150 LPe1150 | ||||||
LPe11002 | ||||||
LPe12002 | ||||||
IBM | No | System P | ||||
FC5716 / FC1977 | ||||||
FC 2315 LX / SX FC 2318 LX / SX FC 2319 LX / SX FC 2320 LX / SX FC 3319 LX / SX FC 3320 LX / SX Ficon Express 4, 10km LX: #3321 Ficon Express 4, SX: #3322 Ficon Express 4, 4km LX: #3324 | Supported Machines: System z z800 - IBM 2066 System z z800 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 System z z9-109 System z z10 2097-E12 System z z10 2097-E26 System z z10 2097-E40 System z z10 2097-E56 System z z10 2097-E64 |
SLES 10 Novell/SuSE
Host Bus Adapter | HBA Firmware | Clustering | Platform & OS Version | |||||
IBM | 8.1.6.8 8.1.10.3 8.2.0.22 8.2.0.48.2p | Veritas DMP 5.0 & 5.1 | Yes | 32 & 64 bit Intel/AMD Based Platforms SP2 2.6.16.60-0.21-smp SP3 2.6.16.60-0.54.5-smp SP4 2.6.16.60-0.103.1-smp | ||||
LP9802 | ||||||||
LP11002 LP1150 | ||||||||
LPe11000 | ||||||||
Device Mapper Multipath | Yes | |||||||
1.10A5 (U3D1.10A5) | ||||||||
8.01.06 8.02.00-k6-SLES10-05 8.2.0.48.2p | Multiflash Image 1.69 (BIOS 2.02) 4.04.09 ( BIOS 2.02) | |||||||
QLA2460 | ||||||||
QLA2462 | ||||||||
QLA2342 | ||||||||
QLE2560 QLE2562 | ||||||||
FC 2319 LX FC 2320 SX Ficon Express 4, 10km LX:#3321 Ficon Express 4, SX: #3322 Ficon Express 4, 4km LX: #3324 Ficon Express 8, 10km LX: #3325 Ficon Express 8, SX: #3326 | Device Mapper Multipath | No | IBM System z System z z800 - IBM 2066 System z z800 - IBM 2086 System z z900 - IBM 2064 System z z990 - IBM 2084 System z z196 - IBM 2817 System z zEC12 - IBM 2827 System z z9-109 System z z10 2097-E12 System z z10 2097-E26 System z z10 2097-E40 System z z10 2097-E56 System z z10 2097-E64 | |||||
SDD | No | IBM System p SP1 2.6.16.46-0.12-ppc64 SP2 2.6.16.60-0.21-ppc64 SP3 2.6.16.60-0.54.5-ppc64 SP4 2.6.16.60-0.103.1-ppc64 | ||||||
FC5758 FC1910 FC1905 FC5759 | ||||||||
IBM | 1.1.0.x 2.1.0.x | Device Mapper Multipath | No | 32 & 64 bit Intel/AMD Based Platforms SP2 2.6.16.60-0.21-smp SP3 2.6.16.60-0.54.5-smp SP4 2.6.16.60-0.103.1-smp | ||||
Brocade 415 Brocade 815 Brocade 425 Brocade 825 | ||||||||
CNA Support | ||||||||
Brocade 1010/1020 CNA | No | 32 & 64 bit Intel/AMD Based Platforms SP2 2.6.16.60-0.21-smp SP3 2.6.16.60-0.54.5-smp SP4 2.6.16.60-0.103.1-smp | Supported with Brocade Fabric Only Volume expansion & contraction is not supported | |||||
QLE8142 | 1.00.95 | No | 32 & 64 bit Intel/AMD Based Platforms SP2 2.6.16.60-0.21-smp SP3 2.6.16.60-0.54.5-smp SP4 2.6.16.60-0.103.1-smp | Supported with Cisco Nexus Only Volume expansion & contraction is not supported |
SLES 11
HBA Driver | Multipathing | SAN Boot | Notes | |||||
Emulex | 1.41a2 FV1.90 | High-Availability-Extension / OpenAIS ( HAE - native cluster ) | 32 & 64 bit Intel/AMD Based Platforms SLES11 U0 | |||||
LP10002 | ||||||||
42D0485 42D0494 | FV 2.50a6 | |||||||
IBM | 8.02.01.03.11.0-k9 | |||||||
QLA2342 | ||||||||
4.06.02 | ||||||||
QLE2560 | ||||||||
QLE2460 | ||||||||
42C1800 | 8.03.00.08.10.3-k4+ DD | |||||||
CNA Support | ||||||||
42C1820 | Device Mapper Multipath | Bo | Supported with Brocade Fabric Only |
Debian
HBA Driver | Multipathing | Notes |
8.2.6 | multipath-tools-0.4.8 | Volume expansion & contraction is not supported Your Debian server may require a reboot if the SAN Volume Controller is restarted |
QLogic | 3.03.21 | |
QLA2460 |
Novell OES2/Xen
HBA Driver | Multipathing | SAN Boot | Notes |
device-mapper-1.02.13-6.9 multipath-tools-0.4.7-34.18 | Boot support for guest operating systems & Servers | Xen hypervisor 3.0.4_13138-0.40 Paravirtualized OES 2 Linux (kernel 2.6.16.46-0.12-xenpae) Paravirtualized OES 2 NetWare 6.5 SP7 | Volume expansion & contraction is not supported Guest OS Paravirtualized SLES 10 SP1 - Domain 0 (kernel 2.6.16.46-0.12-xenpae) Paravirtualized RHEL AS5u1 (kernel 2.6.18-53.el5xen) |
HP-UX 11i v1 for PA-RISC (64-bit only)
Ibm 8212 Drivers For Mac
Host Bus Adapter | Multipathing | SAN Boot |
A5158A | SDD 1.6.3.0 SDD 1.7.0.3 SDD 1.7.1.0 SDD 1.8.0.2 SDD 1.8.1.3 | No |
A6795A | ||
B.11.11.13 B.11.11.16 B.11.11.17 | ||
A9784A | ||
AB379A | Service Guard V11.16 | |
AB378B | ||
AB465A | ||
AD194A |
HP-UX 11i v2 (B.11.23) for PA RISC and Itanium
HBA Driver | San Boot | Platform & OS Version |
B.11.23.0512 B.11.23.0812 | Yes | HP 9000 Series Servers (PA-RISC 64bit) & HP Itanium ServersThe following patches should be applied to the base OS: BUNDLE11i(B.11.23.0409.3) HWEnable11i(B.11.23.0706.064) FEATURE11i(B.11.23.0706.063) QPK1123(B.11.23.0706.064) Set PV (Physical Volume) timeout to 60 seconds when using PV Links. This is to avoid I/O timeouts during fabric maintenance and SAN Volume Controller CCLs (Concurrent code loads) BUNDLE11i B.11.23.0409.3 Required Patch Bundle for HP-UX 11i v2 (B.11.23), FEATURE11i B.11.23.0803.070a Feature Enablement Patches for HP-UX 11i v2, HWEnable11i B.11.23.0712.070 Hardware Enablement Patches for HP-UX 11i v2, OnlineDiag B.11.23.10.05 HPUX 11.23 Support Tools Bundle, QPKAPPS B.11.23.0806.072 Applications Patches for HP-UX 11i v2, QPKBASE B.11.23.0806.072 Base Quality Pack Bundle for HP-UX 11i v2, HPUX11i-OE-MC B.11.23.0712 HP-UX Mission Critical Operating Environment Component |
A6826A | ||
A9782A | ||
AB378A | ||
AB378B | ||
AB465A | ||
AD194A | ||
HP Itanium Servers only |
HP-UX 11i v3 (B.11.31) for PA RISC and Itanium
---
HBA Driver | San Boot | Platform & OS Version |
FibreChannel-00 B.11.31.0803 FibreChannel-00 B.11.31.0809 FibreChannel-00 B.11.31.0812 FibreChannel-00 B.11.31.0903 | Yes | HP 9000 Series Servers (PA-RISC 64bit) & HP Itanium Servers HP requires a disk mapped at LUN0 in order to support CCL (Command Control LUN) and for disk discovery to take place HWEnable11i(B.11.31.0803.318a) FEATURE11i(B.11.31.0803.318b) QPKAPPS(B.11.31.0803.318a) QPKBASE(B.11.31.0803.318a) |
AB378A AB378B AB379A AB379B AB465A AD193A AD194A A9782A A9784A A6826A | FibreChannel-00 B.11.31.0803 FibreChannel-00 B.11.31.0809 FibreChannel-00 B.11.31.0812 FibreChannel-00 B.11.31.0903 | |
No | Veritas Storage Foundation HA v5.0 MP1 Veritas Cluster Server VCS5.0MP1HF2 Please use the following asl-apm package |
SunOS 5.8/Solaris 8 (32 and 64 bit Sparc) *End of Life*
HBA Driver | Multipathing | Clustering | ||
Sun-Badged QLogic (qlc driver) QLogic (qlc driver) | SG-XPCIxxx 2GB SG-XPCIxxx 4GB QLx23xx (2GB) QLx24xx (4GB) | Supplied with SAN package which includes the drivers Select StorageTek SAN 4.4.x on this link. | MPxIO (included in SAN package) | No |
Sun Badged Emulex (emlxs driver) Emulex (emlxs driver) | SG-XPCIxxx (2GB) SG-XPCIxxx (4GB) All Emulex models listed here | Supplied with SAN package which includes the drivers Select StorageTek SAN 4.4.x on this link. |
SunOS 5.9/Solaris 9 (32 and 64 bit Sparc)
Host Bus Adapter | FCode | San Boot | Platform | ||
SG-XPCIxxx 2GB SG-XPCIxxx 4GB QLx23xx (2GB) QLx24xx (4GB) | Supplied with SAN package which includes the drivers Select StorageTek SAN 4.4.x on this link. | Veritas DMP 5.0 (VxVM 5.0MP1RP3 or later required) (download latest ASL here) | SFHA/SFRAC 5.0 MP1 (requires latest ASL available from Symantec) | ||
MPxIO Guidance on Configuring Solaris MPXIO for use with SAN Volume Controller Volumes | SUN Cluster 3.1 & 3.2 (SAN Volume ControllerSupports up to 4-node SUN clusters) | ||||
Sun Badged Emulex (emlxs driver) Emulex (emlxs driver) | SG-XPCIxxx 2GB SG-XPCIxxx 4GB All Emulex models listed here | Supplied with SAN package which includes the drivers Select StorageTek SAN 4.4.x on this link. | Veritas DMP 5.0 (VxVM 5.0MP1RP3 or later required) (download latest ASL here) | SFHA/SFRAC 5.0 MP1 | |
MPxIO Guidance on Configuring Solaris MPXIO for use with SAN Volume Controller Volumes | SUN Cluster 3.1 & 3.2 (SAN Volume Controller Supports up to 4-node SUN clusters) |
SunOS 5.10/Solaris 10 (64 bit)
Host Bus Adapter | FCode | San Boot | Platform | |
SG-XPCIxxx 2GB SG-XPCIxxx 4GB SG-QF8xxx 8GB QLx23xx (2GB) QLx24xx (4GB) QLx25xx (8GB) | Supplied with SAN package | 5.0 (VxVM 5.0MP1RP3 or later required) (download latest ASL here) | SPARC: Yes ( requires kernel patch 118833-36 and qlc driver 119130-33 + 125166-05) x86: No | Sparc & x86 |
MPxIO Guidance on Configuring Solaris MPXIO for use with SAN Volume Controller Volumes | SUN Cluster 3.1 SAN Volume Controller Supports up to 4-node SUN clusters | |||
SG-XPCIxxx 2GB SG-XPCIxxx 4GB SG-QF8xxx 8GB QLx23xx (2GB) QLx24xx (4GB) QLx25xx (8GB) | SUN Cluster 3.2 SAN Volume Controller Supports up to 4-node SUN clusters | |||
Sun Badged Emulex (emlxs driver) Emulex (emlxs driver) | SG-XPCIxxx 2GB SG-XPCIxxx 4GB SG-XPCIxxx 8GB All Emulex models listed here | Supplied with SAN package | MPxIO Guidance on Configuring Solaris MPXIO for use with SAN Volume Controller Volumes | SUN Cluster 3.1 SAN Volume Controller Supports up to 4-node SUN clusters |
SUN Cluster 3.2 SAN Volume Controller Supports up to 4-node SUN clusters | ||||
Veritas DMP 5.0 (VxVM 5.0MP1RP3 or later required) (download latest ASL here) | SFHA/SFRAC 5.0 MP1 | |||
Brocade | 3.0.3.0 | MPxIO Guidance on Configuring Solaris MPXIO for use with SAN Volume Controller Volumes | No |
Ibm 8212 Drivers
Novell Netware 6.5 *End of Life*
Host Bus Adapter | HBA Firmware | Multipathing | SAN Boot | |
QLogic | Native Netware Multipathing Driver | No | IA32_Based Servers (32 bit) 6.5 SP6 IBM has seen an issue with path recovery after a node has been removed from the SAN Volume Controller cluster for an extended period. If this issue is encountered manual rescan of paths is required | |
QLA2342 QLA2342L |
VMware vCenter Site Recovery Manager ( SRM )
vCenter SRM Version | Notes |
ESX 4.0x or higher update *End of Life* | Please visit the VMware SRM Evaluation site for details of SRM Support with SVC and the access to the IBM SVC Storage Replication Adapter SVC supports the use of both Metro & Global Mirror With VMware SRM VMware Site Recovery Manager Storage Partner Compatibility Matrix |
VMware ( ESX/ESXi ) Fibre Channel
Host Bus Adapter | Note |
V4.0 *End of Life* V4.0U1 *End of Life* V4.0U2 *End of Life* V4.1 *End of Life* V4.1U1 *End of Life* | Supported Fibre Channel adapters Listed in the VMware I/O compatibility guide |
Tru64
---
Driver | HBA Firmware | Multipathing | Clustering | SAN Boot | Notes |
Driver Supplied with Operating System | Native Tru64 Multipathing Driver | Yes on HP AlphaServer hosts | AlphaServer 5.1B 5.1B-1 (PK 3) 5.1B-2 (PK 4) 5.1B-3 (PK 5) 5.1B-4 (PK 6) 5.1B-5 (PK 7) | LUN numbering: When mapping vdisks to hosts, only LUNs in the range 0 to 254 can be used Expanding Volumes on the SAN Volume Controller is supported (upon vdisk expansion, the disk label still shows original size however the disk needs to be re labelled and AdvFS file system extended) Shrinking SAN Volume Controller Volumes is not supported SAN Volume Controller Copy Services Configuration / LUN Synthesis: With AdvFS, it is possible to map a FC target to the same machine as a FC source. In order to use the same domain name, manual link to the new disk (ln -s /dev/disk/dskNc) has to be created in the /etc/fdmns/domain_name directory | |
3.92A2 3.93A0 | |||||
1.90A4 1.91x1 1.91x6 | |||||
1.90A4 1.91x1 1.91x6 |
OpenVMS
OpenVMS Alpha
Driver | HBA Firmware | Clustering | Platform & OS Version | |
KGPSA-CA | 3.92A2 3.93A0 | Yes | AlphaServer 8.2 8.3 | Both Alpha and Integrity (I64) Servers are supported LUN numbering: When mapping vdisks to hosts, only LUNs in the range 0 to 254 can be used SAN Volume Controller Volume Expantion and contraction is not supported |
3.92A2 3.93A0 | ||||
1.90A4 1.91x1 1.91x6 |
OpenVMS Integrity (I64)
Host Bus Adapter | Driver | Multipathing | SAN Boot | Notes |
Driver Supplied with Operating System | 2.15 EFI Driver 5 Mar 2010 2.20 EFI Driver 17 May 2010 | Yes | Integrity (I64) 8.2-1 8.3 8.3-1H1 8.4 | Both Alpha and Integrity (I64) Servers are supported LUN numbering: When mapping vdisks to hosts, only LUNs in the range 0 to 254 can be used SAN Volume Controller Volume Expantion and contraction is not supported |
1.76af-2.08 BIOS/2.04 EFI 1 Dec 2009 1.89 -2.15 BIOS/ 2.20 EFI 26 May 2010 | ||||
EFI 4.00a8, FW 2.80a4 10 Sep 2010 |
IBM N series Gateway and NetApp
NetApp & IBM N Series Gateways |
NetApp & N Series Gateway support is available with SVC 6.1.x for selected configurations via RPQ only. Please contact your IBM representative or authorized IBM Business Partner to request support. |
SGI
Firmware | Multipathing | SAN Boot | Notes |
3.3.6 | XVM (incl. in Irix OS) | No | Please visit the Installing section of the SAN Volume Controller Information Center |
OS internal (incl. in SLES SP3 and SGI Pro Pack 4) | No |
z/VSE
Host Bus Adapter | HBA Firmware | Notes |
z/VSE 4.3 and later |
z/VM
Platform | |
z/VM 5.4.0 and later supports Emulated Device (EDEVICE) attachment for all EDEVICE use including paging, spooling, minidisks, and system IPL. z/VM 5.4.0 and later also supports guest attachment via dedicated FCP subchannels. | The following z/VM PTFs are required for EDEVICE use: 5.4.0 - UM32870, UM32716 6.2.0+ - N/A EDEVICE restriction: I/O must be quiesced during Concurrent Code Load (CCL) of a SAN Volume Controller cluster See Linux for System z and z/VSE info for support details regarding guest attachment via dedicated FCP subchannels. |
Apple Mac OS X Server 10.5.x & 10.6.x (32bit)
Host Bus Adapter | ATTO Configuration Tool | Multipathing | SAN Boot |
1.27MP | 2008_08_26 | Mac OS X Flash Bundle 2009_11_13 Atto Multipath Driver Version 3.27MP Atto Multipath Driver Version 3.27MP | No |
Apple Mac OS X Server 10.5.4 Apple Mac OS X Server 10.5.5 | |||
Apple Mac OS X Server 10.5.x Apple Mac OS X Server 10.6.x (32bit) | 1.32MP | 2010_07_28 | ATTO Multipath Driver version 1.3.2 Mac OS X Flash Bundle 2010_07_28 |
CITRIX XEN SERVER Fibre Channel
HBA Driver | Multipathing | San Boot | Platform & OS Version | Notes | |
8.01.7.15 | DMMP | For Guest Operating System support please refer to Citrix | No | XEN SERVER Enterprise Edition v4.1.0 *EoL V5.5 *EoL V5.6 FP1 | Citrix HCL Support Matrix Please see the Information Center for support and configuration details |
IBM System Storageā¢ TS7650G ProtecTIER De-duplication Gateway
Operating System | SAN Boot Support | Notes |
ProtecTIER | No | IBM System Storage TS7650G ProtecTier De-duplication Gateway Please see the Information Center for support and configuration details |
Support for BladeServer Configurations
SAN Volume Controller supports Server Blades that meet all of the following criteria; 1. The Server blade contains Qlogic and Emulex generic chip sets running the IBM or equivalent supported Drivers; and 2. These generic chip sets and drivers are present in the SAN Volume Controller support matrix for HBAs used in non Blade servers; and 3. The Server blade is running an OS that is present in the SAN Volume Controller support matrix; and 4. Either a Fibre Channel pass through module is used in the Blade server chassis to connect the Blades to an external FC network; or |
Examples of specific BladeCentre configurations that IBM includes in SAN Volume Controller interoperability testing currently include:
HS & LS Intel & AMD Models
Blade Operating System | HBA Driver | Multipathing | SAN Boot | |||
For HBA to Chassis compatibility please visit the follow Link & select your Bladecenter Model The IBM HS20 is now End of Service. Bladecenter HS20 ( 8843,8852,7989 ) Bladecenter LS20 ( 8850,8852,7989 ) | Qlogic QLA2342 | SDDDSM 2.1.3.0-1 (Uses MPIO) SDDDSM 2.2.0.0-11(Uses MPIO) SDDDSM 2.4.0.0-9(Uses MPIO) SDDDSM 2.4.1.1-1(Uses MPIO) SDDDSM 2.4.1.2-2(Uses MPIO) SDDDSM 2.4.2.0-1 (Uses MPIO) SDDDSM 2.4.2.1-2 (Uses MPIO) SDDDSM 2.4.3.1-2 (Uses MPIO) SDDDSM 2.4.3.3-2 (Uses MPIO) SDDDSM 2.4.3.3-5 (Uses MPIO) SDDDSM 2.4.3.4-4 (Uses MPIO) | SVC supports up to 8 Windows 2003 nodes per MSCS cluster | Please visit the V6.1.x Software Restrictions document for information regarding Windows SAN Boot Clusters (MSCS) | ||
IBM 48P7061 2Gbps FC Expansion Card IBM 26K4841 - Qlogic QLA2342 IBM 26R0890 - Qlogic QMC2462s IBM 26R0884 - Qlogic QMC2462 | MSCS with Veritas Volume Manager 5.1 | Supported in both 32bit & 64bit windows 2003 Follow this link for installation of device drivers. | ||||
Symantec VERITAS Storage Foundation DMP v4.3 Symantec VERITAS Storage Foundation DMP v5.0 | VERITAS Storage Foundation High Availability v4.3 VERITAS Storage Foundation High Availability v5.0 | We strongly recommend you install Maintenance Pack 1 of VERITAS Storage Foundation v4.3. This can be downloaded with the help of VERITAS Technical Support. Please visit the following release notes: VERITAS Storage Foundation and High Availability Solutions 4.3 Release Notes Please install Veritas Storage Foundation (tm) and High Availability Solutions for Windows 5.0 Rollup Patch 1a (RP1a) Upgrade SVC code level to 4.2.1.3 or later | ||||
2.20.0006 | ||||||
Windows 2008 (32 and 64 bit) Windows 2008 R2 | IBM 48P7061 2Gbps FC Expansion Card IBM 26K4841 - Qlogic QLA2342 IBM 26R0890 - Qlogic QMC2462s IBM 26R0884 - Qlogic QMC2462 | Multiflash Image 1.56 (BIOS 1.24) BIOS 2.10 | MSCS with Veritas Volume Manager 5.1 | Supported in both 32bit & 64bit windows 2008 Follow this link for installation of device drivers. | ||
SDDDSM 2.2.0.0-11(Uses MPIO) SDDDSM 2.4.0.0-9(Uses MPIO) SDDDSM 2.4.1.1-1(Uses MPIO) SDDDSM 2.4.1.2-2(Uses MPIO) SDDDSM 2.4.2.0-1 (Uses MPIO) SDDDSM 2.4.2.1-2 (Uses MPIO) SDDDSM 2.4.3.1-2 (Uses MPIO) SDDDSM 2.4.3.3-2 (Uses MPIO) SDDDSM 2.4.3.3-5 (Uses MPIO) SDDDSM 2.4.3.4-4 (Uses MPIO) | Yes | |||||
2.20.0006 | ||||||
Red Hat EL Advanced Server 4.0 U4 through U8 (32 and 64 bit) *End of Life* | IBM 48P7061 2Gbps FC Expansion Card IBM 26K4841 - Qlogic QLA2342 IBM 26R0890 - Qlogic QMC2462s IBM 26R0884 - Qlogic QMC2462 IBM 39Y9186 - Emulex LP1105BC | Qlogic Multiflash Image 1.56 (BIOS 1.24) Emulex 2.72a2 | Yes | Emulex and QLogic the scsi_timeout value must be set to 60 (default is 30) Parameter settings for QLogic : ql2xfailover=0 ql2xcmdtimermin=15 ql2xmaxqdepth=4 ConfigRequired=0 | ||
No | VSF 4.1 with Maintenance Pack 3 (MP3) (consisting of ASL, APM and DMP fix for SAN.VC array) | |||||
VSF 5.0 HA Maintenance Pack 3 VRTSibmsvc-5.0-1.1_RHEL4.i686.rpm VRTSibmsvcapm-5.0-1.1_RHEL4.x86_64.rpm | ||||||
Device Mapper Multipath | RHEL Cluster Server | Supported with Qlogic HBA's Only SAN boot (IPL) is supported from SVC however the IPL processes can fail because there is no multipath support during the boot processes GFS Li 6.1 is supported with local boot. For RHEL Cluster Server with Emulex HBAs timeout value should be set to 60 (Default 30) | ||||
IBM 48P7061 2Gbps FC Expansion Card IBM 26K4841 - Qlogic QLA2342 IBM 26R0890 - Qlogic QMC2462s IBM 26R0884 - Qlogic QMC2462 IBM 39Y9186 - Emulex LP1105BC | QLogic Multiflash Image 1.56 (BIOS 1.24) Emulex 2.72a2 2.82a3 | Yes | SAN boot (IPL) is supported from SVC however the IPL processes can fail because there is no multipath support during the boot process Remove the ql2xfailover=0 parameter from the IBM modprobe.conf Supported with Emulex 11000 and QLogic 2460 | |||
Steeleye Lifekeeper 6.3.0 Steeleye Lifekeeper V7 | ||||||
Yes | Veritas Storage Foundation HA 5.0 MP3 VRTSibmsvcapm-5.0-1.2_RHEL5.x86_64.rpm | For Emulex & Qlogic the SCSI timout value must be set to 60 ( default is 20 ) | ||||
IBM 48P7061 2Gbps FC Expansion Card IBM 26K4841 - Qlogic QLA2342 IBM 26R0890 - Qlogic QMC2462s IBM 26R0884 - Qlogic QMC2462 | BIOS 1.52 Multiflash Image 1.56 (BIOS 1.24) | No | ||||
SLES 9 SP1,SP2,SP3 *End of Life* | IBM 48P7061 2Gbps FC Expansion Card IBM 26K4841 - Qlogic QLA2342 IBM 26R0890 - Qlogic QMC2462s IBM 26R0884 - Qlogic QMC2462 BM 39Y9186 - Emulex LP1105BC I | Qlogic BIOS 1.52 Multiflash Image 1.56 (BIOS 1.24) Emulex 2.72a2 2.82a3 | SDD 1.6.3.0-5 SDD 1.6.3.0-6 SDD 1.6.3.0-7 SDD 1.6.3.0-8 | No | We recommend using the 2.6.5-7.308-smp kernel. 2.6.5-7.193 and 2.6.5-7.257 kernels are not supported | |
No | Linux-HA Heartbeat 1.2.5 Steeleye Lifekeeper 6.3.0 Steeleye Lifekeeper V7 | |||||
No | VSF 5.0 HA Maintenance Pack 3 VRTSibmsvc-5.0-1.1_SLES9.i586.rpm VRTSibmsvcapm-5.0-1.2_SLES9.x86_64.rpm | |||||
BM 48P7061 2Gbps FC Expansion Card IBM 26K4841 - Qlogic QLA2342 IBM 26R0890 - Qlogic QMC2462s IBM 26R0884 - Qlogic QMC2462 IBM 39Y9186 - Emulex LP1105BC | Qlogic BIOS 1.52 Multiflash Image 1.56 (BIOS 1.24) Emulex 2.72a2 2.82a3 | Yes | Native Cluster With Heartbeat / Stonith Version 2.0.8.0-19 | Vdisk expansion & contraction is not supported SVC Supports two node Native Clusters | ||
No | ||||||
Veritas DMP 5.0 | Veritas Storage Foundation HA 5.0 MP3 VRTSibmsvcapm-5.0-1.2_SLES9.x86_64.rpm | |||||
IBM 48P7061 2Gbps FC Expansion Card IBM 26K4841 - Qlogic QLA2342 IBM 26R0890 - Qlogic QMC2462s IBM 26R0884 - Qlogic QMC2462 BM 39Y9186 - Emulex LP1105BC | Qlogic BIOS 1.52 Multiflash Image 1.56 (BIOS 1.24) Emulex 2.72a2 2.82a3 | Yes (see Notes) | High-Availability-Extension / OpenAIS (HAE - native cluster) sle-hae-release-11-1.12 openais-0.80-3-26.1 | Single path SAN boot Problem: SLES 11Server x86_64 doesn't boot after OS installation on SAN disk. Problem appears when Adaptec Raid controller BIOS (local disk) and Emulex HBA BIOS are active. Solution: Host boots from SAN disk when local disk controller BIOS is disabled. Expand / shrink vdisk Warning: data loss possible !!!!! Documentation: SLES 11 Storage Administration Guide - Chapter 5 | ||
For HBA Support Please see VMware I/O compatibility guide For BladeCenter supported VMware levels please visit IBM BladeCenter Interoperability Guide For SVC supported OS levels please visit VMware OS Supported Levels |
OS | HBA Firmware / BIOS | Multipathing | SAN Boot | |||
Bladecenter HX5 Bladecenter HS21 ( 8853) Bladecenter HS21 XM( 7995 ) The IBM HS21 is now End of Service. Bladecenter HS22 ( 7870,7809) Bladecenter HS22v ( 7871 ) Bladecenter LS21 ( 7971 ) Bladecenter LS22 ( 7901 ) Bladecenter LS41 ( 7972 ) Bladecenter LS42 ( 7902 ) For HBA to Chassis compatibility please visit the follow Link & select your Bladecenter Model | IBM 43W6859 - Emulex 4Gb CFFv IBM 46M6140 - Emulex LPe1205 8Gbps CIOv IBM 24R0890 - Qlogic QMC2462S IBM 39Y9306 - Qlogic QMI3472 IBM 41Y8527 - Qlogic QMI2472 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6065 - Qlogic QMI2572 | Emulex 2.70a5 1.11a9 Qlogic 4Gbps Bios 2.04 FW 4.0.0.27 8Gbps Bios 2.09 FW 5.03.06 | Emulex 2.10A7 Qlogic 9.1.2.19 9.1.7.16 9.1.8.25 9.1.8.35 (With SAN Boot on 44X1940, 44X1945 & 46M6065 Only ) (STORport) | SDDDSM 2.1.3.0-1 (Uses MPIO) SDDDSM 2.2.0.0-11(Uses MPIO) SDDDSM 2.4.0.0-9(Uses MPIO) SDDDSM 2.4.1.1-1(Uses MPIO) SDDDSM 2.4.1.2-2(Uses MPIO) SDDDSM 2.4.2.0-1 (Uses MPIO) SDDDSM 2.4.2.1-2 (Uses MPIO) SDDDSM 2.4.3.1-2 (Uses MPIO) SDDDSM 2.4.3.3-2 (Uses MPIO) SDDDSM 2.4.3.3-5 (Uses MPIO) SDDDSM 2.4.3.4-4 (Uses MPIO) | SVC supports up to 8 Windows 2003 nodes per MSCS cluster | Please visit the V6.1.x Software Restrictions document for information regarding Windows SAN Boot Clusters (MSCS) |
MSCS with Veritas Volume Manager 5.1 | Supported in both 32bit & 64bit windows 2003 Follow this link for installation of device drivers. | |||||
Symantec VERITAS Storage Foundation DMP v4.3 Symantec VERITAS Storage Foundation DMP v5.0 | VERITAS Storage Foundation High Availability v4.3 VERITAS Storage Foundation High Availability v5.0 | We strongly recommend you install Maintenance Pack 1 of VERITAS Storage Foundation v4.3. This can be downloaded with the help of VERITAS Technical Support. Please visit the following release notes: VERITAS Storage Foundation and High Availability Solutions 4.3 Release Notes Please install Veritas Storage Foundation (tm) and High Availability Solutions for Windows 5.0 Rollup Patch 1a (RP1a) Upgrade SVC code level to 4.2.1.3 or later | ||||
Windows 2008 (32 and 64 bit) Windows 2008 SP1, SP2, R2 | IBM 43W6859 - Emulex 4Gb CFFv IBM 46M6140 - Emulex 8Gbps CIOv IBM 24R0890 - Qlogic QMC2462S IBM 39Y9306 - Qlogic QMI3472 IBM 41Y8527 - Qlogic QMI2472 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6065 - Qlogic QMI2572 IBM 00Y3280 - Qlogic QMI8142 2-port 10Gb Converged Network Adapter (CFFh) | Emulex 2.70a5 1.11a9 Qlogic 4Gbps Bios 2.04 FW 4.0.0.27 8Gbps Bios 2.09 FW 5.03.06 Qlogic CNA Multiboot Image 1.01.92 | Emulex 2.10A7 Qlogic 9.1.2.19 9.1.7.16 9.1.8.25 9.1.8.35 ( With SAN Boot on 44X1940, 44X1945 & 46M6065 Only ) (STORport) Qlogic CNA 9.1.8.26 | VERITAS Storage Foundation High Availability Clustering 5.1 | Supported in both 32bit & 64bit windows 2008 Follow this link for installation of device drivers. | |
SDDDSM 2.2.0.0-11(Uses MPIO) SDDDSM 2.4.0.0-9(Uses MPIO) SDDDSM 2.4.1.1-1(Uses MPIO) SDDDSM 2.4.1.2-2(Uses MPIO) SDDDSM 2.4.2.0-1 (Uses MPIO) SDDDSM 2.4.2.1-2 (Uses MPIO) SDDDSM 2.4.3.1-2 (Uses MPIO) SDDDSM 2.4.3.3-2 (Uses MPIO) SDDDSM 2.4.3.3-5 (Uses MPIO) SDDDSM 2.4.3.4-4 (Uses MPIO) | Yes No San Boot with 00Y3280 | |||||
RedHat Enterprise Linux 4 U4 through U8 *End of Life* | IBM 43W6859 - Emulex 4Gb CFFv IBM 46M6140 - Emulex 8Gbps CIOv IBM 24R0890 - Qlogic QMC2462S IBM 39Y9306 - Qlogic QMI3472 IBM 41Y8527 - Qlogic QMI2472 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6065 - Qlogic QMI2572 | Emulex 2.70a5 1.11a9 Qlogic 4Gbps Bios 2.04 FW 4.0.0.27 8Gbps Bios 2.09 FW 5.03.06 | Device Mapper Multipath | Steeleye Lifekeeper 6.3.0 Steeleye Lifekeeper V7 | Emulex and QLogic the scsi_timeout value must be set to 60 (default is 30) Parameter settings for QLogic : ql2xfailover=0 ql2xcmdtimermin=15 ql2xmaxqdepth=4 ConfigRequired=0 | |
No | VSF 4.1 with Maintenance Pack 3 (MP3) (consisting of ASL, APM and DMP fix for SAN.VC array) | |||||
VSF 5.0 HA Maintenance Pack 3 VRTSibmsvc-5.0-1.1_RHEL4.i686.rpm VRTSibmsvcapm-5.0-1.1_RHEL4.x86_64.rpm | ||||||
Yes | Supported with Qlogic HBA's Only SAN boot (IPL) is supported from SVC however the IPL processes can fail because there is no multipath support during the boot processes GFS Li 6.1 is supported with local boot. For RHEL Cluster Server with Emulex HBAs timeout value should be set to 60 (Default 30) | |||||
IBM 43W6859 - Emulex 4Gb CFFv IBM 46M6140 - Emulex 8Gbps CIOv IBM 24R0890 - Qlogic QMC2462S IBM 39Y9306 - Qlogic QMI3472 IBM 41Y8527 - Qlogic QMI2472 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6065 - Qlogic QMI2572 IBM 00Y3280 - Qlogic QMI8142 2-port 10Gb Converged Network Adapter (CFFh) | Emulex 2.70a5 1.11a9 Qlogic 4Gbps Bios 2.04 FW 4.0.0.27 8Gbps Bios 2.09 FW 5.03.06 Qlogic CNA Multiboot Image 1.01.92 |
| device-mapper-multipath | Red Hat Cluster Server | SAN boot (IPL) is supported from SVC however the IPL processes can fail because there is no multipath support during the boot process Remove the ql2xfailover=0 parameter from the IBM modprobe.conf Supported with Emulex 11000 and QLogic 2460 | |
Steeleye Lifekeeper 6.3.0 Steeleye Lifekeeper V7 | ||||||
Yes No San Boot with 00Y3280 | Veritas Storage Foundation HA 5.0 MP3 VRTSibmsvcapm-5.0-1.2_RHEL5.x86_64.rpm | For Emulex & Qlogic the SCSI time out value must be set to 60 ( default is 20 ) | ||||
IBM 24R0890 - Qlogic QMC2462S IBM 39Y9306 - Qlogic QMI3472 IBM 41Y8527 - Qlogic QMI2472 IBM 44X1940 - Qlogic QMI3572 | 4Gbps Bios 2.04 FW 4.0.0.27 8Gbps Bios 2.09 FW 5.03.06 | SDD 1.6.3.0-5 SDD 1.6.3.0-6 SDD 1.6.3.0-7 SDD 1.6.3.0-8 | No | We recommend using the 2.6.5-7.308-smp kernel. 2.6.5-7.193 and 2.6.5-7.257 kernels are not supported | ||
No | Linux-HA Heartbeat 1.2.5 Steeleye Lifekeeper 6.3.0 Steeleye Lifekeeper V7 | |||||
No | VSF 5.0 HA Maintenance Pack 3 VRTSibmsvc-5.0-1.1_SLES9.i586.rpm VRTSibmsvcapm-5.0-1.2_SLES9.x86_64.rpm | |||||
IBM 43W6859 - Emulex 4Gb CFFv IBM 46M6140 - Emulex 8Gbps CIOv IBM 24R0890 - Qlogic QMC2462S IBM 39Y9306 - Qlogic QMI3472 IBM 41Y8527 - Qlogic QMI2472 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6065 - Qlogic QMI2572 IBM 00Y3280 - Qlogic QMI8142 2-port 10Gb Converged Network Adapter (CFFh) | Emulex 2.70a5 1.11a9 Qlogic 4Gbps Bios 2.04 FW 4.0.0.27 8Gbps Bios 2.09 FW 5.03.06 Qlogic CNA Multiboot Image 1.01.92 |
| Yes No San Boot with 00Y3280 | Native Cluster With Heartbeat / Stonith Version 2.0.8.0-19 | Vdisk expansion & contraction is not supported SVC Supports two node Native Clusters | |
No | ||||||
Veritas DMP 5.0 | Veritas Storage Foundation HA 5.0 MP3 VRTSibmsvcapm-5.0-1.2_SLES9.x86_64.rpm | |||||
IBM 43W6859 - Emulex 4Gb CFFv IBM 46M6140 - Emulex 8Gbps CIOv IBM 24R0890 - Qlogic QMC2462S IBM 39Y9306 - Qlogic QMI3472 IBM 41Y8527 - Qlogic QMI2472 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6065 - Qlogic QMI2572 IBM 00Y3280 - Qlogic QMI8142 2-port 10Gb Converged Network Adapter (CFFh) | Emulex 2.70a5 1.11a9 Qlogic 4Gbps Bios 2.04 FW 4.0.0.27 8Gbps Bios 2.09 FW 5.03.06 Qlogic CNA Multiboot Image 1.01.92 |
| Yes (see Notes) | High-Availability-Extension / OpenAIS (HAE - native cluster) sle-hae-release-11-1.12 openais-0.80-3-26.1 | Single path SAN boot Problem: SLES 11Server x86_64 doesn't boot after OS installation on SAN disk. Problem appears when Adaptec Raid controller BIOS (local disk) and Emulex HBA BIOS are active. Solution: Host boots from SAN disk when local disk controller BIOS is disabled. Expand / shrink vdisk Warning: data loss possible !!!!! Documentation: SLES 11 Storage Administration Guide - Chapter 5 | |
VMware ESX ( Please See VMware tables for supported ESX levels & Guest OS ) | IBM 24R0890 - Qlogic QMC2462S IBM 39Y9306 - Qlogic QMI3472 IBM 41Y8527 - Qlogic QMI2472 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6065 - Qlogic QMI2572 | For HBA Support Please see VMware I/O compatibility guide For BladeCenter supported VMware levels please visit IBM BladeCenter Interoperability Guide | Native VMware Multipathing | |||
IBM 00Y3280 - Qlogic QMI8142 2-port 10Gb Converged Network Adapter (CFFh) |
JS Power Models
AIX 5.1 & 5.2 are now end of service and as such no further fixes will be made available. Should you have an issue please upgrade to a supported version of AIX
IBM Server | HBA | Multipathing | SAN Boot | |||
Bladeserver JS12 ( 7998 ) | IBM 39Y9306 - Qlogic QMI3472FC 8252 IBM 41Y8527 - Qlogic QMI2472FC 8248 IBM 43W6859 - Emulex 4Gb CFFvFC 8251 | SDD 1.6.3.0-5 SDD 1.6.3.0-6 SDD 1.6.3.0-7 SDD 1.6.3.0-8 SDD 1.6.3.0-9 | No | |||
device-mapper-multipath | No | |||||
device-mapper-multipath | Yes | |||||
Driver included in TL Level | Please refer to OS Tables for latest support information | |||||
VIOS 2.1.1 Supported Clients Please see the following APAR when using the System i family OS | Driver included in VIOS version | MPIO with SDDPCM 2.5.1.0 MPIO with SDDPCM 2.6.0.1 MPIO with SDDPCM 2.6.3.2 MPIO with SDDPCM 2.6.4.0 MPIO with SDDPCM 2.6.5.1 See Flash for APAR & efix information | Yes (SVC support for boot from SAN on LPAR for both VIO Server or Guest OS) | |||
IBM 41Y8527 - Qlogic QMI2472FC 8248 | ||||||
IBM 43W6859 - Emulex 4Gb CFFvFC 8251 | ||||||
AIX 5.3 TL12 EOL: extended service contract only. | IBM 26R0884 - Qlogic QMC2462 IBM 48P7061 2Gbps FC Expansion Card | |||||
SLES8 *End of Life* | ||||||
AIX 5.1 | IBM 39Y9306 - Qlogic QMI3472FC 8252 IBM 41Y8527 - Qlogic QMI2472FC 8248 IBM 26R0890 - Qlogic QMC2462s IBM 39Y9186 - Emulex LP1105BC | Please refer to OS Tables for latest support information | ||||
AIX 5.3 TL12 EOL: extended service contract only. | ||||||
Driver included in distro | ||||||
AIX 5.3 TL12 EOL: extended service contract only. | IBM 39Y9306 - Qlogic QMI3472FC 8252 IBM 41Y8527 - Qlogic QMI2472FC 8248 IBM 43W6859 - Emulex 4Gb CFFvFC 8251 | Please refer to OS Tables for latest support information | ||||
SLES10 | ||||||
Red Hat 4.6 Red Hat 4.7 *End of Life* | ||||||
VIOS 2.1.1 Supported Clients Please see the following APAR when using the System i family OS | Driver included in VIOS version | Please refer to OS Tables for latest support information | ||||
IBM 41Y8527 - Qlogic QMI2472FC 8248 | ||||||
IBM 43W6859 - Emulex 4Gb CFFvFC 8251 | ||||||
RHEL 5.4 RHEL 5.5 | IBM 39Y9306 - Qlogic QMI3472FC 8252 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6140 - Emulex LPe1205 8Gbps CIOv IBM 46M6065 - Qlogic QMI2572 4Gbps CIOv | Please refer to OS Tables for latest support information | ||||
AIX 5.3 TL12 EOL: extended service contract only. | ||||||
AIX 6.1 | ||||||
VIOS 2.x Supported Clients Please see the following APAR when using the System i family OS | ||||||
Bladeserver PS700 Power 7 Technical overview | IBM 39Y9306 - Qlogic QMI3472FC 8252 IBM 44X1940 - Qlogic QMI3572 IBM 44X1945 - Qlogic QMI2582 IBM 46M6140 - Emulex LPe1205 8Gbps CIOv IBM 46M6065 - Qlogic QMI2572 4Gbps CIOv | Please refer to OS Tables for latest support information | ||||
AIX 5.3 TL12 EOL: extended service contract only. | ||||||
AIX 6.1 | ||||||
VIOS 2.x Supported Clients Please see the following APAR when using the System i family OS |
HP BladeSystem Support
HBA Support | Supported Operating Systems | |
BL30p BL40p BL25p BL35p BL460c BL465c BL480c BL685c | 300874-B21 354054-B21 361426-B21 381881-B21 394588-B21 403619-B21 | Please Visit the HP Support Website for recommended device driver information |
iSCSI Host Attachment
Please refer to the following documentation for details on supported operating systems, restrictions and recommendations for iSCSI attachment to SAN Volume Controller
V6.1.0 - SAN Volume Controller Information Center for iSCSI Host Attachment
Software Initiator Supported Operating Systems ( Hardware Initiators are currently not supported by SAN Volume Controller )
Only the listed operating systems are supported for attaching hosts to an IBM System Storage SAN Volume Controller using iSCSI: |
|
These restrictions supersede information published in the hard-copy, PDF and online forms of the IBM System Storage SAN Volume Controller product documentation.
- Maximum of 64 iSCSI hosts per I/O group, maximum of 256 iSCSI hosts per cluster.
iSCSI Host Attachment Recommendations
These recommendations supplement the information published in the hard-copy, PDF and online forms of the IBM System Storage SAN Volume Controller product documentation. These configuration recommendations are not mandatory for a supported configuration.
- For best performance:
- iSCSI host and SAN Volume Controller node Ethernet ports should be directly connected to the same switch
- Ethernet switches should be used in preference to hubs
- iSCSI host and SAN Volume Controller node Ethernet ports should be running at the same link speed
- For best results, all links used for iSCSI traffic should operate at 1Gb/s full duplex.
- If you are using IBM Tivoli Storage Productivity Center (TPC) or equivalent application to monitor the performance of your SAN Volume Controller cluster, it is recommended to separate this management traffic from iSCSI host I/O traffic, such as using node port 1 for management IPs and node port 2 for iSCSI IPs.
Controllers
Please refer to the Configuration Guide or SAN Volume Controller Information Center which details the recommended customer configurable settings that should be applied for each storage controller type.
IBM Storwize V7000
Firmware | Support for MDisks >2TB |
IBM Storwize V7000 | Yes |
IBM DS3000
Firmware | ESM | Attachment | Notes |
06.70.22.XX 06.70.24.XX Samsung usb driver for mac. Ocz revodrive hybrid driver. This tool will download and update the correct OCZ SSD driver versions automatically, protecting you against installing the wrong SSD drivers. 06.70.69.XX Mar 30, 2017Ā Canon PIXMA MP287 Printer driver download We are here to help you to find complete information about full features driver and software. Select the correct driver that compatible with your operating system. Canon mp287 printer driver download for mac. Download Canon pixma mp287 driver for windows and macintosh.The Pixma MP287 offers incredible print speed up to 8.4 ppm and maximum resolution up to 4800 x 1200 dpi. You can print your favourite and beautiful moment using the Full HD Movie Print. Canon PIXMA MP287 Driver Installer: Steps to install the downloaded software and driver for Canon PIXMA MP287 Driver: If the download is complete and you are ready to install the driver, click Open, and click the downloaded file. Guidelines for Installing Canon PIXMA MP287 Printer Driver and Software For Mac OS Users The presence a Canon MP287 installation file is essential. If you have not already, download the setup file first and remember where the downloaded files are stored on your Mac OS-based unit. Canon PIXMA MP287 Driver Download for Windows, MAC and Linux ā the PIXMA MP287 makes everyday printing, copying and scanning tasks easier than ever before.Colour inkjet printer, copier and scanner, ISO standard print speed (A4): up to 8.4ipm (Mono), Media: A4, Letter, photo stickers and more. 7.35.41.XX 7.35.53.XX | 0186 or higher | FC | Concurrent download of ESM code with I/O is not supported. Do not reboot both controllers simultaneously. SAN Volume Controller Supports SAS and SATA Drive configurations. Single Controller configuration is not supported. RAID-5 Array size must be 4+1 or larger. RAID-6 Array size must be 4+1+1 or larger. Ensure Host type is set to 'IBM TS SAN VCE'. DS3400 maximum LUNs per partition is currently 32, limiting the number of LUNs from a single DS3400 to a single SAN Volume Controller cluster to 32 Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
07.70.xx.xx 07.83.18.xx 07.84.xx.xx 07.86.32.00 *07.86.40.xx See Notes* | *From earlier versions of 7.86.xx.xx this is not a concurrent upgrade please see the following Technote.* Concurrent download of ESM code with I/O is not supported. Ensure Host type is set to 'IBM TS SAN VCE'. Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | ||
07.60.xx.xx 07.83.18.xx 07.84.xx.xx |
IBM DS4000
Firmware | ESM Support | Support for MDisks >2TB | ||
DS4100 | Download the recommended version of the Storage Manager from the DS4000 website | Concurrent download of ESM firmware with I/O is not supported | No | Dynamic expansion of controller LUNs is not supported Please refer the DS4000 website for the latest recommended DS4000 client software and RDAC levels Please refer the DS4000 website for specific configuration guidelines, cabling requirements & restrictions when attaching EXP810 to DS4300 & DS4500 DS4000 copy services (FlashCopy, VolumeCopy, MetroMirror) can be used with SAN Volume Controller RAID-5 Array size must be 4+1 or larger. RAID-6 Array size must be 4+1+1 or larger. DS4000 range maximum LUNs per partition is currently 256, limiting the number of LUNs from a single DS4000 to a single SAN Volume Controller cluster to 256. * Please see the following DS4K flashes DS4200 DS4700 DS4800 If you have 07.36.08.xx code, you MUST contact DS4000 support prior to upgrading to your DS4000 firmware. The 07.36.08.xx release is no longer supported. Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 06.60.22.xx 07.15.07.xx 07.15.10.xx 07.36.14.xx 07.36.17.xx 07.50.13.xx 07.60.28.xx | ||||
06.12.56.xx | ||||
06.12.56.xx 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 06.60.22.xx | Concurrent download of ESM firmware with I/O is supported with controller firmware 06.23.05.00 or later . | |||
06.12.56.xx 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 06.60.22.xx | ||||
06.12.56.xx 06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 06.60.22.xx | ||||
06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 06.60.22.xx 07.15.07.xx 07.15.10.xx 07.36.14.xx 07.36.17.xx 07.50.13.xx 07.60.28.xx 07.60.40.xx | ||||
06.23.05.xx 06.60.02.xx 06.60.08.xx 06.60.17.xx 06.60.22.xx 07.15.07.xx 07.15.10.xx 07.36.14.xx 07.36.17.xx 07.50.13.xx 07.60.28.xx 07.60.40.xx |
FAStT (The IBM TotalStorage FAStT Family has been renamed the IBM TotalStorage DS4000 Series)
Firmware Release | Supports SAN Volume Controller Quorum Disks | Notes | |
05.30.25.xx | Download the recommended version of the Storage Manager from the DS4000 website | No | Dynamic expansion of controller LUNs is not supported Concurrent download of ESM firmware with I/O is not supported DS4000 copy services (FlashCopy, VolumeCopy, MetroMirror) can be used with SAN Volume Controller. Please refer the DS4000 website for the latest recommended DS4000 client software and RDAC levels Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
05.30.25.xx |
IBM DS5000
Controller Model | Storage Manager | Supports SAN Volume Controller Quorum Disks | Notes |
07.60.xx.xx 07.83.18.xx 07.84.xx.xx | Download the recommended version of the Storage Manager from the DS5000 website | No | Dynamic expansion of controller LUNs is not supported Please refer the DS5000 website for the latest recommended DS5000 client software and RDAC levels Please refer the DS5000 website for specific configuration guidelines, cabling requirements & restrictions when attaching EXP5000 and EXP810 DS5000 copy services (FlashCopy, VolumeCopy, MetroMirror) can be used with SAN Volume Controller. DS5000 range maximum LUNs per partition is currently 256, limiting the number of LUNs from a single DS5000 to a SAN Volume Controller cluster to 256. RAID-5 Array size must be 4+1 or larger RAID-6 Array size must be 4+1+1 or larger Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
07.30.21.xx 07.36.14.xx 07.36.17.xx 07.50.12.xx 07.50.13.xx 07.60.xx.xx 07.83.18.xx 07.84.xx.xx |
IBM DS6000
Firmware | Support for MDisks >2TB | ||
DS6800 | For further support, including interoperability details & latest supported code levels, visit the DS6800 support pages | No | DS6000 copy services (FlashCopy, MetroMirror) can be used with SAN Volume Controller. Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
IBM DS8000
---
Model | Supports SAN Volume Controller Quorum Disks | Notes |
For further support, including interoperability details & latest supported code levels, visit the 8100 support pages | No | DS8000 copy services (FlashCopy, MetroMirror) can be used with SAN Volume Controller. DS8700 Thin provisioning is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
For further support, including interoperability details & latest supported code levels, visit the 8300 support pages | ||
For further support, including interoperability details & latest supported code levels, visit the 8700 support pages DS8700 Code Bundle Information | ||
For further support, including interoperability details & latest supported code levels, DS8800 Support & Downloads |
IBM ESS
Firmware | Support for MDisks >2TB | |
2105-E10 | Yes (Also supports Extended Quorum) | Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
2105-F10 | ||
2105-800 | ||
2105-750 |
XIV
Model | Supports SAN Volume Controller Quorum Disks | Notes |
9.2.0g | No | XIV advanced functions ( Native copy services and Thin Provisioning ) are not supported with SAN Volume Controller Do not attempt to create 512 LUNs The current maximum number of LUNS supported is 511 |
10.0 | XIV advanced functions ( Native copy services and Thin Provisioning ) are not supported with SAN Volume Controller Do not attempt to create 512 LUNs with 10.0 fimware The current maximum number of LUNS supported is 511 | |
10.0.0a 10.0.1b 10.1.0a 10.2.0a 10.2.1 10.2.2 10.2.2a 10.2.4 10.2.4a 10.2.4b 10.2.4c 10.2.4e 11.0.0 11.0.0a 11.0.1 11.1 11.1.0b 11.1.1 11.2 11.3 11.4 | XIV advanced functions ( Native copy services and Thin Provisioning ) are not supported with SAN Volume Controller XIV Concurrent code upgrade is supported from XIV code levels 10.1.0a & 10.1.0b to XIV code level 10.2.0a and above. Please consult your XIV TA prior to performing any upgrades on XIV. Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems Concurrent Upgrade from 10.2.2 to 10.2.2a is not supported |
HP
Model | AKA | Support for MDisks >2TB | |
MSA1000 | No | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | |
MSA2000 | |||
Firmware | Supports SAN Volume Controller Quorum Disks | Notes | |
VCS 3.110 VCS 4.007 VCS 4.100 | No | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Refer to EVA product documentation for concurrent maintenance procedures Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | |
Model | AKA | Support for MDisks >2TB | |
EVA 4000 | Yes | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Refer to EVA product documentation for concurrent maintenance procedures Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | |
EVA 8000 | |||
XCS 6.100 XCS 6.110 XCS 6.2xx | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Refer to EVA product documentation for concurrent maintenance procedures Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | ||
EVA 8100 | |||
1100.1000 | |||
---|---|---|---|
No | Dynamic expansion of controller LUNs is not supported EVA Advanced Functions such as Continuous Access are not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | ||
Model | AKA | Support for MDisks >2TB | |
XP48 | HDS 9910 | No | Your HP support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Ensure that you wait until each Volume is formatted before you present it to the SAN Volume Controller. Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems XP24000 & 20000 advanced function such as thin provisioning are not supported |
HDS 9960 | |||
21-14-46-00/00 | |||
XP1024 | |||
XP10000 | HDS NSC55 | ||
XP12000 | |||
XP24000 | HDS USPv | ||
HDS USPv m | |||
70-01-61/00 | Yes ( See Notes ) | Quorum disk requires host mode 39 : Please contact your HDS support representative |
Hitachi Data Systems
Firmware | Supports SAN Volume Controller Quorum Disks | Notes | ||
These Products are End Of Service and as such are no longer formally supported | ||||
Thunder 9530V / 9570V | ||||
9585V | ||||
Firmware | Supports SAN Volume Controller Quorum Disks | Notes | ||
These Products are End Of Service and as such are no longer formally supported | ||||
9970V | ||||
Hitachi | AKA | Support for MDisks >2TB | ||
NSC55 | No | Your HDS support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported An SAN Volume Controller configuration must include at least one storage controller which supports SAN Volume Controller quorum disks Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems Ensure that you wait until each Volume is formatted before you present it to the SAN Volume Controller. USPv & USPv m advanced function such as thin provisioning are not supporte | ||
USP600 | ||||
USPv | XP24000 | |||
XP20000 | ||||
70-01-61/00 | Yes ( See Notes ) | Quorum disk requires host mode 39 : Please contact your HDS support representative | ||
Firmware | Supports SAN Volume Controller Quorum Disks | Notes | ||
0786/C & earlier | Yes | Your HDS support representative will perform hardware maintenance and firmware upgrade procedures. Although these operations are nondisruptive to SAN Volume Controller firmware upgrades should be performed with low levels of host I/O or when host I/O has been quiesced Dynamic expansion of controller LUNs is not supported HDS Advanced Function such as Thin Provisioning are not supported with SAN Volume Controller at this time Please set the host type for AMS2xxx to Windows. Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | ||
0893 & earlier |
EMC
EMC Clariion | Supports SAN Volume Controller Quorum Disks | Notes |
02.19.200.5.xxx | No | Your EMC support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
02.19.400.5.xxx | ||
02.19.600.5.xxx | ||
02.19.300.5.xxx 02.26.300.5.xxx | ||
02.19.500.5.xxx 02.26.500.5.xxx | ||
02.19.700.5.xxx 02.26.700.5.xxx | ||
03.26.010.5.xxx | Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | |
03.26.020.5.xxx | ||
03.26.040.5.xxx | ||
03.26.080.5.xxx | Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | |
04.28.000.5.xxx 04.28.000.5.504 04.29.000.5.003 04.29.000.5.006 04.30.000.5.508 | We recommend the customers who are running Raid 6 to upgrade to the latest supported firmware. Advanced Functions such as thin provisioning are not supported with SAN Volume Controller Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | |
CX4-480 | ||
FC4700 | Your EMC support representative will perform hardware maintenance and firmware upgrade procedures. Concurrent hardware maintenance operations are non-disruptive to SAN Volume Controller. This product requires I/O to be quiesced during firmware upgrade Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems | |
Support for MDisks >2TB | ||
8000 Series (8130, 8230, 8430, 8530, 8730, 8830) | Yes | If you have DMX attached to SAN Volume Controller, please see the following flash: Invalid Configurations on EMC Symmetrix Your EMC support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Symmetrix copy services (SRDF etc.) can be used with SAN Volume Controller. Refer to the following hint & tip for more information: Data Encryption functionality is not supported with SAN Volume Controller. Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
Enginuity 5671 | ||
Enginuity 5772 Enginuity 5773 | ||
Enginuity 5772 Enginuity 5773 | ||
5874 5875 |
Sun StorEdge
Firmware | Supports SAN Volume Controller Quorum Disks | Notes |
01-19-99-00/04 | No | Your Sun support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
01-19-99-00/04 | ||
9970 | HDS 9970V | |
HDS 9980V | ||
50-09-06-00/00 | ||
50-09-85-00/00 50-09-90-00/00 |
StorageTek
StorageTek D-Series
Model | NVSRAM | Supports SAN Volume Controller Quorum Disks | AKA |
D173 | N2772-530855-006 | Yes | |
5.39.01.00 5.40.19.00 6.10.15.00 6.12.10.00 | N4884-530855-005 N4884-540855-005 N4884-610855-006 N4884-612855-003 | ||
D220 | N2882-534855-003 | ||
D240 | N2882-540855-007 N288X-610855-006 N288X-612855-003 | AKA FlexLine 240 | |
5.30.23.00 5.40.19.00 6.10.15.00 6.12.10.00 | N5884-530855-005 N5884-540855-005 N588X-610855-006 N588X-612855-003 | AKA FlexLine 280 | |
6.15.12.00 | 9.15.G2.01 |
StorageTek FlexLine 200 Series
Model | NVSRAM | Supports SAN Volume Controller Quorum Disks | AKA |
FLX210 | N282X-612855-003 | Yes | |
6.12.10.00 | AKA D240 | ||
6.12.10.00 | AKA D280 | ||
6.15.12.00 | 9.15.G2.01 |
StorageTek 6000 Series
Model | Supports SAN Volume Controller Quorum Disks | Notes |
06.16.81.10 06.60.xx.xx 07.70.xx.xx | No | Your Sun support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
6140 | ||
06.60.xx.xx | ||
07.70.xx.xx |
IBM N Series Filer and NetApp FAS
IBM N Series | Firmware | Support for MDisks >2TB |
N/A | No | Your IBM or NetApp support representative will perform hardware maintenance and firmware upgrade procedures. These operations are non-disruptive to SAN Volume Controller Dynamic expansion of controller LUNs is not supported Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems Note: host type should be set to Linux |
960 | ||
N3300 2859-A20 | DataONTAP 7.2.4 DataONTAP 7.3 DataONTAP 7.3.1 DataONTAP 7.3.2 DataONTAP 7.3.4 DataONTAP 7.3.5.1 | |
FAS2050A | ||
270 | ||
3020 | ||
3040 | ||
3050 | ||
3070 | ||
3140 | ||
3160 | ||
3170 | ||
6030 | ||
6040 | ||
6070 | ||
6080 |
Fujitsu Eternus
Model | Supports SAN Volume Controller Quorum Disks | Notes |
100 | Yes | Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems Dynamic expansion of controller LUNs is not supported |
V30L21 V30L27 | ||
V20L86 V20L91 | ||
600 | ||
V20L56 V10L61 | ||
700 | ||
V20L56 V20L61 | ||
700B | ||
100 | ||
300 | ||
400 | ||
600 | ||
900 | ||
1200 | ||
2200 | ||
410 | ||
440 | ||
8100 | ||
8700 | ||
DX60 | ||
DX80 |
Bull
Firmware | Support for MDisks >2TB | |
StoreWay FDA1500 | Yes | Minimum supported SAN Volume Controller 6.1 version 6.1.0.8 Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
StoreWay FDA2900 | ||
StoreWay Optima 1500 | ||
StoreWay Optima 2000 | ||
StoreWay Optima 3000 |
NEC iStorage
Model | Supports Storwise V7000 Quorum Disks | Notes |
436 | No | Minimum supported SAN Volume Controller 6.1 version 6.1.0.8 Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems |
S2900 |
Pillar Data
Model | Supports SAN Volume Controller Quorum Disks | Notes |
1.6.6 | No | |
2.8.6 | ||
03.03.07 04.02.00 |
Texas Memory Systems
Firmware | Support for MDisks >2TB |
RamSan 500 | Yes |
RamSan 630 |
Xiotech
Firmware | Support for MDisks >2TB |
Emprise 5000 | Yes |
Nexsan
Firmware | Support for MDisks >2TB |
SATABeast | Yes |
Dell Compellent
Firmware | Support for MDisks >2TB | |
Dell Compellent | Yes | Please visit the SAN Volume Controller Information Center for details on Configuring and Servicing external storage systems Compellent storage is not supported in NPIV mode with SAN Volume Controller Compellent Advanced Functions are not supported with SAN Volume Controller |
Switches
SAN Volume Controller supports NPIV products in the SAN with the restriction that these products can only be used for host attachment. An example of an NPIV product is the Brocade Access Gateway module for the BladeCenter.
FCIP technology listed on the IBM SAN Support pages can be used in SAN Volume Controller configurations for the following uses:
1) iSCSI host attachment. Please refer to the iSCSI Host Attachment section for more information.
2) Links between two SAN Volume Controller clusters in a Metro Mirror or Global Mirror configuration. Please refer to the Configuration Guide for details
All blades comprising of ISWL ports are supported in SAN Volume Controller configurations, provided that they are listed on the IBM SAN Support pages. This includes the Cisco MDS 9000 Family 4-port 10Gbps Fibre Channel Switching Module and the Brocade 10Gbps Fibre Channel blade. |
For BladeCenter switch module, Passthrough module, switch vendor interconnectivity and supported firmware levels, please visit the IBM BladeCenter support website |
Brocade
Firmware | AKA | |||
2005-B16 *End of Life* | 6.1.0c 6.1.0d 6.1.0e 6.1.0f 6.1.0g 6.1.0h 6.1.1a 6.1.1b 6.1.1c 6.1.2 6.1.2b 6.1.2c 6.2.2b 6.2.2d 6.2.2e 6.2.2f | *End of Life* SAN16B-2 Silkworm 200E EMC DS-16B2 | ||
6.1.1a 6.1.1b 6.1.1c 6.1.2 6.1.2b 6.1.2c 6.2.0c 6.2.0e 6.2.0f 6.2.0g 6.2.1b 6.2.2b 6.2.2d 6.3.0b 6.3.1a 6.3.1b 6.3.2 6.3.2b 6.4.0a 6.4.0b 6.4.0c 6.4.1a 6.4.2a 6.4.3b 6.4.3c 6.4.3d 6.4.3e 6.4.3f | SAN256B Silkworm 48000 | |||
5.3.0d 5.3.1a 5.3.1b 5.3.2 5.3.2b 5.3.2c | *End of Life* SAN Switch H08 / 16 Silkworm 3250 / 3850 | |||
6.1.1a 6.1.1b 6.1.1c 6.1.2 6.1.2b 6.1.2c 6.2.0c 6.2.0e 6.2.0f 6.2.0g 6.2.1b 6.2.2b 6.2.2d 6.3.0b 6.3.1a 6.3.1b 6.3.2 6.3.2b 6.4.0a 6.4.0b 6.4.0c 6.4.1a 6.4.2a 6.4.3b 6.4.3c 6.4.3d 6.4.3e | *End of Life* SAN32B-2 Silkworm 4100 | |||
*End of Life* SAN64B-2 Silkworm 4900 | ||||
5.3.0d 5.3.1a 5.3.1b 5.3.2 5.3.2b 5.3.2c | *End of Life* SAN Switch F32 Silkworm 3900 EMC DS-32B2 | |||
Director | ||||
2109-M12 *End of Life* | Director | |||
2005-B5K *End of Life* | 6.1.1a 6.1.1b 6.1.1c 6.1.2 6.1.2b 6.1.2c 6.2.0c 6.2.0e 6.2.0f 6.2.0g 6.2.1b 6.2.2b 6.2.2d 6.3.0b 6.3.1a 6.3.1b 6.3.2 6.3.2b 6.4.0a 6.4.0b 6.4.0c 6.4.1a 6.4.2a 6.4.3b 6.4.3c 6.4.3d 6.4.3e | *End of Life* Silkworm 5000 SAN32B-3 20055KB | ||
6.1.1a 6.1.1b 6.1.1c 6.1.2 6.1.2b 6.1.2c 6.2.0c 6.2.0e 6.2.0f 6.2.0g 6.2.1b 6.2.2b 6.2.2d 6.3.0b 6.3.1a 6.3.1b 6.3.2 6.3.2b 6.4.0a 6.4.0b 6.4.0c 6.4.1a 6.4.2a 6.4.3b 6.4.3c 6.4.3d 6.4.3e 6.4.3f 7.0.0a 7.0.0b 7.0.0c 7.0.0d 7.0.1b 7.0.2a 7.0.2c 7.1.0c 7.1.1 7.1.1b 7.1.1c 7.1.1c1 7.2.0d 7.2.1a 7.2.1b 7.2.1c 7.2.1c1 | Brocade DCX Brocade DCX-4s | |||
Fabric Switch | ||||
Brocade Converged Network Switches | ||||
IBM | Firmware | Notes | ||
8000 | 6.4.0b 6.4.0c 6.4.1b 6.4.2a 6.4.3 7.0.0c 7.0.0d 7.0.1b 7.0.2a 7.0.2c 7.1.0c 7.1.1 7.1.1b 7.1.1c 7.1.1c1 | SVC/V7000 node to node clustering is now supported over Fibre channel or FCoE. |
Cisco MDS
Firmware | AKA | |
3.1(3a) 3.2(2c) 3.2(3a) 3.3(1a) 3.3(1c) 3.3.2 3.3.3 3.3.4 4.1.1(c) 4.1.3(a) 4.2.1b 4.2.3 4.2.5 4.2.7a 4.2(7b) 5.0(1a) 5.0(4b) 5.2.1 5.2(2) 5.2(2a) 5.2(2d) 5.2(6) 5.2(6a) 5.2(6b) 5.2(8) 5.2(8a) 5.2(8b) 5.2(8c) 6.2(1) 6.2(3) 6.2(7) 6.2(9) | ||
3.1(3a) 3.2(2c) 3.2(3a) 3.3(1a) 3.3(1c) 3.3.2 3.3.3 3.3.4 4.1.1(c) 4.1.3(a) 4.2.1b 4.2.3 4.2.5 4.2.7a 4.2(7b) 5.0(1a) 5.0(4b) 5.2.1 5.2(2) 5.2(2a) 5.2(2d) 5.2(6) 5.2(6a) 5.2(6b) 5.2(8) 5.2(8a) 5.2(8b) 5.2(8c) 6.2(1) 6.2(3) 6.2(7) 6.2(9) | ||
2062-E11 2054-E11 | ||
3.1(3a) 3.2(2c) 3.2(3a) 3.3(1a) 3.3(1c) 3.3.2 3.3.3 3.3.4 4.1.1(c) 4.1.3(a) 4.2.1b 4.2.3 4.2.5 4.2.7a 4.2(7b) 5.0(1a) 5.0(4b) 5.2.1 5.2(2) 5.2(2a) 5.2(2d) 5.2(6) 5.2(6a) 5.2(6b) 5.2(8) 5.2(8a) 5.2(8b) 5.2(8c) | ||
5.0(1a) 5.0(4b) 5.2.1 5.2(2) 5.2(2a) 5.2(2d) 5.2(6) 5.2(6a) 5.2(6b) 5.2(8) 5.2(8a) 5.2(8b) 5.2(8c) 6.2(1) 6.2(3) 6.2(7) 6.2(9) | ||
3.1(3a) 3.2(2c) 3.2(3a) 3.3(1a) 3.3(1c) 3.3.2 3.3.3 3.3.4 4.1.1(c) 4.1.3(a) 4.2.1b 4.2.3 | ||
2061-020 | ||
2061-420 |
Model | Class | Notes |
4.1(3)N1(1) 4.1(3)N2(1a) 4.2(1)N2(1) 5.0(3)N2(1) 5.0(3)N2(2) 5.2(1)N1(2) | SVC/V7000 node to node clustering is now supported over Fibre channel or FCoE. | |
Supported behind core MDS switches with Qlogic CNA ( Combined Network Adapters ) Please see the OS tables above for support OS/CNA combinations |
McDATA
McDATA Model | Class | Notes | |||
IBM# for McDATA Badged Switch | |||||
ES-3016 **End of Life** | Sphereon Fabric Switch | ||||
ES-3032 **End of Life** | 2031-032 | ||||
ES-3216 **End of Life** | 2031-216 | ||||
ES-3232 **End of Life** | 2027-232 | ||||
IBM SAN24M-1 **End of Life** | Sphereon Fabric Switch | 2031-224 | |||
ES-4400 **End of Life** | 2026-416 | ||||
ES-4700 **End of Life** | 2026-432 | ||||
Intrepid Director | EMC ED-64M | ||||
ED-6140 **End of Life** | 2027-140 | EMC ED-140M | |||
IBM SAN256M **End of Life** | EOSn 09.09.00 09.09.02 09.09.03 09.09.05 09.09.06 09.09.07 | 2027-256 |
Qlogic
Model | Class | Notes |
V6.8.0.03 | Max 64 hosts per I/O Group 128 host N port logins per IO group (64 per node port) | |
9000 |
Other Hardware & Software
Technologies for extending the distance between two SAN Volume Controller clusters can be broadly divided into the following two categories.
Inter Cluster Fibre Channel Extenders
Fibre channel extenders simply extend a fibre channel link by transmitting fibre channel packets across long links without changing the contents of those packets. IBM has tested a number of such fibre channel extender technologies with SAN Volume Controller and will support fibre channel extenders of all types provided that they are planned, installed and operated as described in the Configuration Guide document.
Inter Cluster SAN Routers
SAN routers extend the scope of a SAN by providing 'virtual nPorts' on two or more SANs. The router arranges that traffic at one virtual nPort is propagated to the other virtual nPort but the two fibre channel fabrics are independent of one another. Thus nPorts on each of the fabrics cannot directly log into each other. There are distance restrictions imposed due to latency. The amount of latency which can be tolerated depends on the type of copy services being used (Metro Mirror or Global Mirror). Details of the maximum latencies supported can be found in the Software Installation and Configuration Guide.
Due to the more complex interactions involved, IBM explicitly tests products of this class for interoperability with SAN Volume Controller.
The following SAN Routers are supported for use with SAN Volume Controller when planned, installed and operated as described in the Configuration Guide document.
Inter Cluster SAN Routers | AKA | ||
IBM# for IBM Badged Switch | |||
McDATA Eclipse 1620 SAN Router | 2027-R04 | The Advanced Functions Router pairs for HA Configurations & iFCP Fast Failover in EOSi 5.01.00 are not supported at this time | |
McDATA Eclipse 2640 SAN Router | |||
SAN16B-R SAN Router | 7.4.1d | ||
SAN18B-R | 6.3.1b 6.3.2a 6.4.0b 6.4.0c | ||
SAN04B-R | 6.3.1b 6.3.2a 6.4.0a | ||
SAN06B-R | 6.3.1a 6.3.1b | ||
M48 FC3450 Blade | 6.3.1b 6.3.2a 6.4.0a 6.4.0b 6.4.0c | ||
Cisco MDS 9000 Series Inter VSAN Routing | |||
2.4.4.3 |
VSS
VSS | ||
Windows 2003 | SAN Volume Controller Support for Microsoft Volume Shadow Copy Service (VSS) | Please use the following link for information on Microsoft VSS Version 4.5 |
Management GUI
To access the Management GUI, you must ensure that your web browser is supported and has the appropriate settings
enabled
Support links |
For information on supported browsers & configuring your browser to work with the SAN Volume Controller GUI please visit the SAN Volume Controller Information Center Configuring -> Creating a Cluster -> Checking your web browser settings for the management GUI |
GPFS / RVSD Versions
AIX Level | RVSD | Note |
3.4 | N/A | Persistent Reservations are not supported Please see the following link for GPFS Documentation |
3.4 3.5 | ||
3.4 3.5 |
GPFS | RVSD/PSSP | ||
5.6 and above | Please see the following link for GPFS Documentation |
TPC Level | Note |
V6.1.0.0 | Please visit the following link for the IBM TotalStorage Productivity Center for Disk Minimum level required for clusters containing 2145-CF8 nodes with solid-state drives (SSDs) is V4.1.1.55 |
TotalStorage Productivity Center for Replication
TPC for Replication can be used with Metro Mirror and Global Mirror. Please visit the TPC for Replication support website for details |
Oracle
*Oracle Server Release | Minimum SVC Level | ASM | |
9i | V6.1.x | Not Supported | AIX 5.1 & AIX 5.2 are now end of service and as such no further fixes will be made available. Should you have an issue please upgrade to a supported version of AIX. AIX 5.3 TL12 is now EOL: extended service contract only. Please visit the 6.1 SAN Volume Controller restrictions document for further information |
AIX 5.1 AIX 5.2 AIX 5.3 TL12 AIX 6.1 RHEL4 RHEL5 SLES9 SLES10 HPUX11iV2 Windows 2003 Windows 2008 Solaris 9 Solaris 10 | Yes | ||
10g | AIX 5.1 AIX 5.2 AIX 5.3 TL12 AIX 6.1 AIX 7.1 RHEL4 RHEL5 SLES9 SLES10 HPUX11iV2 Windows 2003 Windows 2008 Solaris 9 Solaris10 | Yes | |
11gR1 64bit | AIX 5.1 AIX 5.2 AIX 5.3 TL12 AIX 6.1 AIX 7.1 RHEL4 RHEL5 SLES9 SLES10 HPUX11iV2 Windows 2003 Windows 2008 Solaris 9 Solaris10 |